__max_num_config_instances: &max_num_config_instances 2
module_name: battery_status
parameters:
- group: Battery Calibration
definitions:
BAT${i}_V_DIV:
description:
short: Battery ${i} voltage divider (V divider)
long: |
This is the divider from battery ${i} voltage to ADC voltage.
If using e.g. Mauch power modules the value from the datasheet
can be applied straight here. A value of -1 means to use
the board default.
type: float
decimal: 8
reboot_required: true
num_instances: *max_num_config_instances
instance_start: 1
default: [-1.0, -1.0]
BAT${i}_A_PER_V:
description:
short: Battery ${i} current per volt (A/V)
long: |
The voltage seen by the ADC multiplied by this factor
will determine the battery current. A value of -1 means to use
the board default.
type: float
decimal: 8
reboot_required: true
num_instances: *max_num_config_instances
instance_start: 1
default: [-1.0, -1.0]
BAT${i}_V_CHANNEL:
description:
short: Battery ${i} Voltage ADC Channel
long: |
This parameter specifies the ADC channel used to monitor voltage of main power battery.
A value of -1 means to use the board default.
type: int32
reboot_required: true
num_instances: *max_num_config_instances
instance_start: 1
default: [-1, -1]
BAT${i}_I_CHANNEL:
description:
short: Battery ${i} Current ADC Channel
long: |
This parameter specifies the ADC channel used to monitor current of main power battery.
A value of -1 means to use the board default.
type: int32
reboot_required: true
num_instances: *max_num_config_instances
instance_start: 1
default: [-1, -1]