esc_calibration.cpp
5.92 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
/****************************************************************************
*
* Copyright (c) 2015-2017 PX4 Development Team. All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
*
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in
* the documentation and/or other materials provided with the
* distribution.
* 3. Neither the name PX4 nor the names of its contributors may be
* used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
* FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
* COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
* BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS
* OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
* AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
* ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*
****************************************************************************/
/**
* @file esc_calibration.cpp
*
* Definition of esc calibration
*
* @author Roman Bapst <roman@px4.io>
*/
#include "esc_calibration.h"
#include "calibration_messages.h"
#include "calibration_routines.h"
#include <drivers/drv_hrt.h>
#include <drivers/drv_pwm_output.h>
#include <px4_platform_common/defines.h>
#include <px4_platform_common/posix.h>
#include <px4_platform_common/time.h>
#include <systemlib/mavlink_log.h>
#include <uORB/Subscription.hpp>
#include <uORB/topics/battery_status.h>
using namespace time_literals;
bool check_battery_disconnected(orb_advert_t *mavlink_log_pub)
{
uORB::SubscriptionData<battery_status_s> batt_sub{ORB_ID(battery_status)};
const battery_status_s &battery = batt_sub.get();
batt_sub.update();
if (battery.timestamp == 0) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "battery unavailable");
return false;
}
// Make sure battery is disconnected
// battery is not connected if the connected flag is not set and we have a recent battery measurement
if (!battery.connected && (hrt_elapsed_time(&battery.timestamp) < 500_ms)) {
return true;
}
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Disconnect battery and try again");
return false;
}
int do_esc_calibration(orb_advert_t *mavlink_log_pub)
{
int return_code = PX4_OK;
hrt_abstime timeout_start = 0;
calibration_log_info(mavlink_log_pub, CAL_QGC_STARTED_MSG, "esc");
uORB::SubscriptionData<battery_status_s> batt_sub{ORB_ID(battery_status)};
const battery_status_s &battery = batt_sub.get();
batt_sub.update();
bool batt_connected = battery.connected;
int fd = px4_open(PWM_OUTPUT0_DEVICE_PATH, 0);
if (fd < 0) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Can't open PWM device");
return_code = PX4_ERROR;
goto Out;
}
/* tell IO/FMU that its ok to disable its safety with the switch */
if (px4_ioctl(fd, PWM_SERVO_SET_ARM_OK, 0) != PX4_OK) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Unable to disable safety switch");
return_code = PX4_ERROR;
goto Out;
}
/* tell IO/FMU that the system is armed (it will output values if safety is off) */
if (px4_ioctl(fd, PWM_SERVO_ARM, 0) != PX4_OK) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Unable to arm system");
return_code = PX4_ERROR;
goto Out;
}
/* tell IO to switch off safety without using the safety switch */
if (px4_ioctl(fd, PWM_SERVO_SET_FORCE_SAFETY_OFF, 0) != PX4_OK) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Unable to force safety off");
return_code = PX4_ERROR;
goto Out;
}
calibration_log_info(mavlink_log_pub, "[cal] Connect battery now");
timeout_start = hrt_absolute_time();
while (true) {
// We are either waiting for the user to connect the battery. Or we are waiting to let the PWM
// sit high.
static constexpr hrt_abstime battery_connect_wait_timeout{20_s};
static constexpr hrt_abstime pwm_high_timeout{3_s};
hrt_abstime timeout_wait = batt_connected ? pwm_high_timeout : battery_connect_wait_timeout;
if (hrt_elapsed_time(&timeout_start) > timeout_wait) {
if (!batt_connected) {
calibration_log_critical(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Timeout waiting for battery");
return_code = PX4_ERROR;
goto Out;
}
// PWM was high long enough
break;
}
if (!batt_connected) {
if (batt_sub.update()) {
if (battery.connected) {
// Battery is connected, signal to user and start waiting again
batt_connected = true;
timeout_start = hrt_absolute_time();
calibration_log_info(mavlink_log_pub, "[cal] Battery connected");
}
}
}
px4_usleep(50000);
}
Out:
if (fd != -1) {
if (px4_ioctl(fd, PWM_SERVO_SET_FORCE_SAFETY_ON, 0) != PX4_OK) {
calibration_log_info(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Safety switch still off");
}
if (px4_ioctl(fd, PWM_SERVO_DISARM, 0) != PX4_OK) {
calibration_log_info(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Servos still armed");
}
if (px4_ioctl(fd, PWM_SERVO_CLEAR_ARM_OK, 0) != PX4_OK) {
calibration_log_info(mavlink_log_pub, CAL_QGC_FAILED_MSG, "Safety switch still deactivated");
}
px4_close(fd);
}
if (return_code == PX4_OK) {
calibration_log_info(mavlink_log_pub, CAL_QGC_DONE_MSG, "esc");
}
return return_code;
}